“Completely dead” almost never means the battery is destroyed. Work this sequence — it resolves most no-power cases with nothing more than a flashlight and patience.
1. The obvious things, properly
- Charge indicator state — verify the wall outlet and charger LED actually confirm charge is flowing, not merely plugged in.
- Power switch position: many models carry both a physical switch and a button-hold requirement.
2. The connection points
- Battery seat: unclip and reseat firmly; terminals oxidise and mates loosen with vibration.
- Display and controller plugs: unplug, look for bent pins, reseat.
- Any accessible fuse or breaker: visual continuity plus a meter check; a fuse can fail without looking wrong.
- Dead cells, failed controllers and broken harnesses are bench work; note what you tested and how before requesting support, so the claim moves fast.
- Fleet owners: log serials — battery batches share lifetimes, and one failure is information about its siblings.
3. The protection logic
A BMS that tripped on low voltage may need a slow recovery charge from its own charger before it re-enables output — “won’t turn on after running flat” is this, not death.
4. When it truly is hardware
The charger-light guide and the brake-check companion continue the triage series in the RMG Knowledge Base; per-model protection behaviour is documented on product pages.